This release resolves defects identified through the following support incidents
Module / Application
Description
E3D Design
Title: Hard coded password/security issue Resolution: Fixed – affected files have been modified/removed from the product.
E3D Design
Title: Wrong Fix Tube dimension in Isometric Resolution: Fixed – application checks if a PCOM is followed by a flange when calculating dimensions.
E3D Design
Title: LaaS randomly occured issue -> Unhandled Exception: System.TimeoutException: Pipe message send timed out Resolution: Fixed – Added a retry on the refresh mechanism to account for periods of un-responsiveness.
E3D Design
Title: Long element description (rtext, stext, ttext) causes unstable behavior or crash of E3D Resolution: Fixed – increased code robustness for object descriptions exceeding 250 characters (RText, SText and TTtext fields).
E3D Design
Title: Token lifetime issue Resolution: Fixed – We’ve now added a refresh to this mechanism to account for such cases and believe that this will resolve the issue.
E3D Design
Title: Adding additional folder structure to AVEVA_DESIGN_USER does not evaluate the newly created folder and crashes Resolution: Fixed – unhandled exception no longer presented on dismissing Error message on adding additional folder structure to AVEVA_DESIGN_USER.
E3D Design
Title: Reference Grid tagging does not behave as expected with – (dash) character Resolution: Fixed – when a dash is used within the StartId, rather than an underscore, the number is incremented as expected.
E3D Design
Title: Cannot WAITon a non-blocking form or display any form from a WAITon form. Resolution: Fixed – application prevents the PML error; displaying an alert and clears when there is a waiting stateform.
E3D Design
Title: Getwork performance test in E3D 3.1.9 test build. Resolution: Fixed – a Hull & Outfitting environment variable has been extended to AVEVA E3D Design (DB_N_DBPAGES_TO_READ environment variable). With this variable enabled, performance improvements have been observed—particularly in scenarios where data is stored and accessed sequentially.
Title: Issue on Move>Offset dialog box Resolution: Fixed – In Move>Offset and Copy>Offset forms, when using “WRT world” setting, the axes are displayed “ENU” or “XYZ” depending on the value in Project > Options > Configuration > Coordinates > Format. The aid axes displayed in the 3D view will reflect the same axis labels as the control.
E3D Design
Title: Non-persistent filter value when using Cable Data for equipment zone Resolution: Fixed – Filtered cable data is displayed on “Reload Cables” based on the zone selected.
E3D Design
Title: The client is setting up the des-purpose file and needs to us AS as a purpose and it is not working correctly when creating a zone Resolution: Fixed – when applying a purpose that is the same as one of the valid keywords associated with PURP, i.e. PURP AS. The command is handled and the WORD keyword is inserted. So for example, PURP AS becomes PURP WORD AS, meaning that the correct interpretation of the purpose command is used.
E3D Design
Title: Issue About q unset(!A) will cause E3D Crash Resolution: Fixed – Added missing support for PMLVAR
E3D Design
Title: Switching E3D to XYZ Coordinates Resolution: Fixed – application updated to resynchronize settings group with system setting post running of client init file.
E3D Design
Title: Issue with IFC property import in E3D Resolution: Fixed – identified property sets are successfully imported.
E3D Design
Title: Licensing.SDK is not initialized properly in a E3D .NET Standalone Application Resolution: Fixed – Licensing.SDK is initialized in a E3D .NET Standalone Application.
E3D Design
Title: Laas errors while working on projects Resolution: Fixed – The fix restarts the process: Aveva.Connect.Sdk.Daemon.exe when this LaaS error occurs.
E3D Design
Title: Need to Update the Release Letter of E3D3.1.9.1 / E3D3.1.10 – MultiCAD1.09.exe Resolution: We have updated the product release note for E3D3.1.10 with the following information: Note: MultiCAD should be installed as part of the normal application of the AVEVA E3D Design patching process. If for any reason, Multicad is not installed automatically, the application can be installed manually by using the MultiCAD1.10.msi that accompanies this fix release pack. On this basis we can confirm that for existing and future versions, MultiCAD should install automatically alongside E3D, but if for any reason this is not the case, the application can be updated manually.
E3D Design
Title: E3D 3.1.7.2 not working with LaaS, if running as an Administrator Resolution: Fixed
E3D Catalogue
Title: Documentation is missing for ‘Move to Limbo’ settings in AVEVA E3D Catalogue Resolution: Fixed – Missing information is documented and will be available as part of E3D 3.1.10 documentation.
E3D Catalogue
Title: Paragon module loadUserCommands function Fluent UI customisations Resolution: Fixed – able to call loadUserCommands function hence allowing for Fluent UI customisations.
Lexicon
Title: Error running the IntegrationSetup_LexiconMacros.dat Resolution: Fixed – handled error.
Piping
Title: PARAGON – Problems with numeric STYP Resolution: Fixed – In specon mode if STYP is provided with TEXT ‘1234’, then while modifying the value in Paragon, it stores the value in Tanswer rather than answer.
Piping
Title: Incorrect outside diameter value on P3 of TEE is output Resolution: Fixed – querying the outside diameter (P3OD attribute) of a tee connected to an offleg reducer now returns the correct diameter.
Piping
Title: Mirroring piping components ends up to an error Resolution: Fixed – application considers the current selection of items apart for TUBI.
Piping
Title: PIPE COMP EDITOR initially not allowing the selection of a reducing COUP Resolution: Fixed – config buttons remain enabled, which will let the user flip between them even in cases where no components are available in the first config.
Piping
Title: The PTNHEAD or PTNTUBE for the TUBI PARTNO does not match the PTNTUBE of the previous component or the PTNHEAD of the previous branch head. Resolution: Fixed – Added a check for components with fitLength 0 so that these do not become the start points of new pieces
Piping
Title: Piping – Tees alignment on sloping pipe Resolution: Fixed – A fix has been made to show the correct Tee orientation on sloped / falling lines.
Piping
Title: Branch connection Error to PCOM (or any items with more than 3 connection ppoints) in Pipe Editor Modify Pipe Resolution: Fixed – validation corrected for selected p-point bore for the cross and similar types.
Piping
Title: Piping Subcomponents still cannot be exported to RVM in E3D 3.1.9. Resolution: Fixed – sub-components now exported
Piping
Title: Update Atts… fails to be shown for PDAREF’s mismatch SPCO vs. GPART when PDAREF of SPEC is unset Resolution: Fixed – Prompt/Alert the user to update the pdaref’s on spec when the Pdaref on SPECO is not equal to Pdaref on the Gpart when the pdaref is nullref/unset on SPEC.
Piping
Title: Branch sketching – helpers (points or mirroring plane) are left behind when form is closed Resolution: Fixed – helper points and mirror plane removed after closing the form upon clearing all aids referencing them.
Piping
Title: Pipe spool drawing problem for leave side tube Resolution: Fixed – Inclination angle [INCL] value displayed on the spool drawings.
Piping
Title: The piping construction arrow does not change it direction when you switch from “with flow2 to “against flow” Resolution: Fixed – arrow indicating the construction direction changes direction and changing flow in the create component form.
Piping
Title: Piping Component Editor – Select: Create Mode and Skipping Connected Comps – strange behavior and unexpected results Resolution: Fixed – application updated to ensure correct component for tracking method to update the aids.
Piping
Title: Problem with STYPE selector Resolution: Fixed – no additional pipe is generated when working with modified/derived valves.
Piping
Title: Copy Mirror – when using Collection, function is aborted by a pop-up error Resolution: Fixed – application considers the current selection of items apart for TUBI.
Piping
Title: Pipe schedules of the reducer is displayed not right in the SDTE Resolution: Fixed – A change has been made to the order of expression evaluation of concatenation which will fix this defect.
Piping
Title: Bad lstube reference after reducer creation Resolution: Fixed – correction to lstube selection.
Piping
Title: Branch connection Error to PCOM (or any items with more than 3 connection ppoints) in Pipe Editor Modify PipeE3D3.1.9/UE3.0 Resolution: Fixed – validation corrected for selected p-point bore for the cross and similar types.
Piping
Title: Pipe Assemblies do not work when they are made of a side branch connected to a PCOM Resolution: Fixed – able to form Pipe Assemblies where including a side branch connected to a PCOM with a connecting P3.
HVAC
Title: Lost refs for HVAC when migrating from E3D 2.1 to 3.1 Resolution: Fixed – In the install ‘data’ directory e.g. C:\AVEVA\E3D Design4.3\data there will be a file named upgradebendref.pmlmac Please check that the bend reference is upgraded correctly (it no longer shows as having an illegal reference) after the latest ACP is installed. The file can be dragged and dropped into the command window. The position in the hierarchy must be somewhere above where the bend is located.
Structures
Title: Welds are not transferred for the joints as ENDATU Resolution: Fixed – Changed the error message from “An error occurred when importing weld information from the Catalog. A valid End Datum connection reference is required for this weld” to “An error occurred when importing weld information from the Catalog. The welds in this end datum are not valid unless it is connected to a panel”.
Structures
Title: Problem for Merge structure panels. Resolution: Fixed – multiple plates can merge without any crating duplicate negative PAVE points, and the negative PAVE points can be modified without any errors.
Structures
Title: StruClassification Limitations Resolution: Fixed – When multiple USDAs are defined for the STRUCLASS attribute for different element types, this is now respected by the property grid value list. The value lists in these two areas now properly reflect the USDA values: Sections > Defaults > Structural Classification Plates > Defaults > Panel Classification
Structures
Title: DRNEND DRNSTART not updated correctly after editing with Move Resolution: Fixed – after relocating the GENSEC or STWALL, the Start/End direction angle remains unchanged and maintains the original angle.
Structures
Title: Create Closed Handrail but failed Resolution: Fixed – Fixed – Closed layout mode handrails now appear correctly
Structures
Title: E3D Model Structural Copy of Subs – NCYL Bug with graphics representation Resolution: Fixed – negative shown correctly in PANE in identified scenario.
Structures
Title: Building: Problems with SCTNs converted to GENSECs Resolution: Fixed – where converting handrails or sloping floors from SCTN to GENSEC, the orientation is not erroneously impacted on modification.
Structures
Title: Building: Issues with extrusion interface for room volume Resolution: Fixed – when expanding a rectangular room, an additional point is no longer created and the origin of the rectangular (room) shape is retained.
Structures
Title: Building: Problem creating ladders Resolution: Fixed – error is not presented on creating a ladder using building application.
Structures
Title: Building: Modifying position of wall does not result in warning on enclosed room Resolution: Fixed – Main Building form turns red for a room where an enclosing wall has had its position attribute modified.
Structures
Title: Building: Modifying position of STWALL or FLOOR does not result in warning on enclosed room Resolution: Fixed –
Structures
Title: Posstart Difference in Handrail Between E3D Versions 3.1.7.2 and 3.1.9.1 Resolution: Fixed – Due to DRNS/DRNE being set parallel to rail. If this scenario is encountered the DRNS/DRNE value is now ignored.
Structures
Title: Handrail mitre and trim is incorrect after upgrade to E3D 3.1.9.1 Resolution: Fixed – mitred rails at the start/end now operate correctly with x offset.
Supports
Title: Slow performance of supports application when accessing E3D via Citrix or RDP Resolution: Fixed – E3D Supports application performance is better.
Supports
Title: E3D 3.1 Supports – Witch Hanger Interface Error. Resolution: Fixed – error is longer presented on using Witch Hanger interface and modification of created Support.
Supports
Title: MDS Hanger Support Issue – VH07, VH08 and VH47 Resolution: Fixed – application adapted for identified type supports (VH07, VH08 and VH47) to recognise two rods.
Supports
Title: Mirror Copy a GENSEC keeps jumping to the STRU Resolution: Fixed – mirror copy operates as designed where GENSEC is part of a SUPPORT ZONE.
Supports
Title: How to set different units for dimensions in FT/VT supports Resolution: Fixed – able to enter Deg and N suffixes to the text boxes in the Support Editor form for angle and Load units. The user is also able to use Force type.
Supports
Title: User Defined Ancillaries – Catalogue Copy – Copy Process Failed and Stopped Resolution: Fixed – check function works correctly for invalid references. Additionally, the form now has resizing capability.
Supports
Title: FT09 support creation on the vertical pipe is incorrect Resolution: Fixed – Support creation on the vertical pipe with desired template is intact.
Supports
Title: Special supports – Using LUG as associated supports with E3D 3.1.8.1 Resolution: Fixed – convert to special now considers lugs and other associated ancillaries during conversion process.
Supports
Title: Issue with relocation of double pedestal support. Resolution: Fixed – Double pedestal support positions properly.
Supports
Title: Support FT29: wrong detail text Resolution: Fixed – model change to correct FT29 Detail Text
Supports
Title: Error copying a Support, when using Inch Bore Units Resolution: Fixed – Unit conversion is handled.
Supports
Title: Impossible to use a DbListing of a SUPPO Resolution: Fixed – added a check for the type ANCI to consider it for LAXE Calculations.
Supports
Title: Support modelling: how to activate the option ‘add associated ancillary? for vessel support Resolution: Fixed – VT20 & VT21 are extended for add associate functionality.
Supports
Title: Hanger template is created but cannot be Modified Resolution: Fixed – identified Hanger template can be modified post creation.
Supports
Title: Imperial units change to metric units after receiving this error “Insufficient clearance for minimum required rod length” Resolution: Fixed – Imperial units no longer change to metric units after receiving this error “Insufficient clearance for minimum required rod length” when trying to place a hanger where the pipe is too close to the supporting steel above.
Title: When we add XGT01 guide to AT108 for insulated pipe below error show up Resolution: Fixed – no error is presented when adding XGT01 guide to AT108 for insulated pipe.
Supports
Title: FT34A has no description on isometric BOM. Resolution: Fixed – Shows description on isometric BOM
Supports
Title: AN04 DESP are not updated in following workflow Resolution: Fixed – when the shoe height is changed, a confirmation window appears. If “Yes” is selected, the shoe height and the heights of the referenced ancillaries will be updated accordingly.
Supports
Title: Cannot apply FT46 to 250mm flange – we receive error “Could not find a template for the bore size of the pipe selected” Resolution: Fixed – Model change to AVEVA Projects for FT46 Support.
Supports
Title: Misalignment of SUPC hpos and tpos When Changing Associated Ancillary via “Reselect Ancillary Type” Resolution: Fixed – no misalignment in creation when changing the Associated Ancillary using Reselect Ancillary Type.
Supports
Title: MTOC Setting Error in Structure Standard Defaults Modification UI Resolution: Fixed – MTOC setting updated correctly
Cable
Title: While auto routing cables, after applying the filter we need extra filtered item & selected Item count for verification and tracking. Resolution: Fixed – able to filter selected items in Cable Data form.
Cable
Title: The3D model graphical representation does not display correctly Resolution: Fixed – Cable representation has been improved. Cables that cannot be visualized as cylinders are now drawn as lines. This will be further enhanced in upcoming releases.
Cable
Title: Gap is coming between Cable tray reducer and Straight Resolution: Fixed – fixed by a project update
Cable
Title: (61,620) F&M: Value is invalid – When opening Modify Cable way Branch Resolution: Fixed – no error message is presented on switching from circular to rectangular cable way modify branch workflow.
Cable
Title: Strange behavior of Auto-Route if Cables do not enter the CWAY Resolution: Fixed – no error message is presented on switching from circular to rectangular cable way modify branch workflow.
Cable
Title: manual routing does not pick branch Resolution: Fixed – Cableway Entry/Exit list populated where manually routing cable.
Title: Add material form can’t find correct component from Spec table Resolution: Fixed – Add Material form locate correct component from Specification Table
Cable
Title: Strange behaviour of Auto-Route if Cables do not enter the CWAY Resolution: Fixed – auto-route enters CWAY as expected for given scenario.
Cable
Title: When the client adds conduit bends with different radiuses to the spec it will not dress the conduit Resolution: Fixed – adding conduit bends with different radiuses to the specification does not negatively impact the dressing of the conduit.
Cable
Title: There appears to be a bug with the Min. Length Straight Tray default setting. Resolution: Fixed – corrected imperial conversion for Min. Length Straight Tray default setting.
Cable
Title: Fitting-to-Fitting coupler (FFC) position issue in MASTER/VANTRUNK-CATA Resolution: Fixed in AVEVA Projects 3.1.10.
Cable
Title: Auto-Dressing not working when the conduit is connected with rectangular tray Resolution: Fixed – error no longer presented for given scenario where auto-dressing a CWBRAN when it’s connected to a Rectangular CWBRAN.
Cable
Title: When modifying or creating a CWBRAN and the inside radius approaches the width the software is presenting an error Resolution: Fixed – no error is presented on creating or modifying CWBRAN where the inside radius ‘approaches’ the branch width.
Cable
Title: Issue when trying to route cable in manual using E3D 3.1.9.1 – cblCable.pmlfrm Resolution: Fixed – Cableway Entry/Exit list populated where manually routing cable.
Isometrics
Title: Length of first TUBI in BRAN will be added to previous TUBI if MTOH of a branch is DOTD Resolution: Fixed – Cut pipe length table no longer includes pipe lengths when previous pipes where DOTD.
Isometrics
Title: Overall dimension point error – COSW coupling Resolution: Fixed – error is not presented where last component in Isometric line is a Coupling and symbol key is COSW.
Isometrics
Title: NSBC and weld table cause Isodraft dimension problem Resolution: Fixed – dimensioning format consistent for weld numbering options (From DB or Off).
Isometrics
Title: When running the isometric drawing with a pipe that includes the unnecessary PCON and PBOR data defined in INST (Skey JXFL) at P33 and P34, a fatal error occurs. Resolution: Fixed – unhandled exception is no longer presented for identified examples where (superfluous) PCON and PBOR data defined within INST Skey.
Isometrics
Title: Dimensional error in isometric Resolution: Fixed – Dimensions have been fixed when we have a support on an elbow with a page break.
Isometrics
Title: Combination between a cold bent bend and penetration atta gives wrong dimensions under certain conditions Resolution: Fixed – remove unnecessary check between tube and bend lengths preventing correct calculation of dimension in certain scenarios.
Isometrics
Title: Reducing elbow displays incorrectly with IsoDraft setting “Dimension Composite” turned on Resolution: Fixed – account for reducing elbow records in the transfer file when determining the end of a pipe section.
Isometrics
Title: Setting MTOR attribute of Tee-set-on components increases the pipe weight on the isometric material list Resolution: Fixed – Tee-set-on’s are now ignored from the MTOR of their parent pipe.
Isometrics
Title: Error in overall dimension Resolution: Fixed – Overall dimensions are now shown correctly when they involve an un-dimensioned tee.
Isometrics
Title: The exported IDF file contains invalid symbols for production Resolution: Fixed – Large coordinate values are correctly output to the transfer file (idf) and a new error message is generated to the user if we cannot correct the large coordinates.
Isometrics
Title: Wrong slopes showing in Isometric drawings Resolution: Fixed – Fall markers less than 1:500 will no longer be displayed on isometrics. An issue with different pipe lengths between fall markers being on/off has also been resolved.
Isometrics
Title: Slope in pipe containing Support ATTAs. Resolution: Fixed – check for uncommented attas removed from the checking mechanism
Isometrics
Title: Spool Break PL function doesn’t work when a component has supports Resolution: Fixed – Spools will now split at the elbow point.
Draw
Title: How to export OLAY elements and hatching in different layers while exporting the drawing to DWG/DXF from Draw module. Resolution: Fixed – Layers are assigned to Olay and View block references
Draw
Title: DWG import to E3D Draw Issue Resolution: Fixed – Leader line is imported as exploded and described issues with linear dimension (colour, terminator and text position) have been fixed.
Draw
Title: VLAYRF for GRDRLR element is only as attribute, missing in Properties form Resolution: Fixed – added new property “Layer” in Representation section of Property Grid for Grid Ruler.
Draw
Title: Confusing description of “Paste Object with Original Coordinates” function Resolution: Fixed – behaviour works as designed. Changes to documentation (‘Paster Object with Original Coordinates’).
Draw
Title: “Paste Object with Original Coordinates” multiplies unnecessarily the scale Resolution: Fixed – improved calculation for paste object with original coordinate operations.
Draw
Title: “Automatic update design” disengages unexpectedly Resolution: Fixed – an automatic update design is triggered regardless of View Frame setting in the set view limits form.
Draw
Title: DRAW crashes with a specific linestyle Resolution: Fixed – circle primitive drawn with identified user-defined line style exports successfully to pdf format.
Draw
Title: When a hole is created in a PANE element for a corrugated bulkhead using an NXTR element, an issue arises in E3D 3.1.8.1’s Draw where the hole size varies depending on the Arctolerance of the VIEW. Resolution: Fixed – where identified circles were previously drawn with slightly too small a radius, they are now drawn with the exact radius (i.e. no longer depending on the Arctolerance setting).
Draw
Title: Non orthogonal model geometry is represented as sequential straight lines, not circles in drawings exports Resolution: Fixed – circle and arc-fitting are now enabled in all views.
Draw
Title: Imported 2D DWG AILINs shift or offset in the VIEW if repositioned after import Resolution: Fixed – Made DRSIGF schema changes to fix how AIDGRO behaves in Draw with transforms.
Draw
Title: 3D Coordinate advanced label – Picking P-point of extrusions seems to be faulty Resolution: Fixed – resolution to enable and usage of indicated P-points (of extrusion) where using advance label 3D Coordinate picks.
Draw
Title: Location Defined form: changing View Style makes the View Scale unset Resolution: Fixed – scale is set on changing View Style.
Draw
Title: Attribute PRBLNK is showing incorrect value as OFF Resolution: Fixed – improvement made to the definition of the PRBLNK attribute.
Draw
Title: Improvement of tooltip when creating section planes Resolution: Fixed – tooltip updated to avoid confusion in purpose.
Draw
Title: Opening linked drawing (not sheet) leads to fatal error Resolution: Fixed – unhandled exception resolved and opening a drawing will open its first sheet.
Draw
Title: Opened drawing via link lacks views content Resolution: Fixed – opened drawing via link no longer opens in read-only mode.
Draw
Title: Error exporting to PDF with file path length near 256 characters Resolution: Fixed – when filepath length with appended search pattern “*.png” extends limit of 260 characters, application displays error message prompting user to shorten file name.
Draw
Title: Blocking of Backing Sheet Resolution: Fixed – Backing sheets are now exported as exploded on model space, not as a block when Blocking Backing Sheet option is disabled
Draw
Title: Back element claimed by Update command Resolution: Fixed – Prevent backing sheets being unnecessarily claimed in Draw. This prevents the unnecessary session comment.
Draw
Title: Issue dimensioning panels in E3D 3.1.9.1 Resolution: Fixed – PAVE P-Points under a PANE are restored and have the correct position.
Draw
Title: P-point snap to pane elements Resolution: Fixed – PAVE p-points under a PANE are restored and have the correct position.
Interop
Title: Problems on positions in a RVM file on binary mode when the model uses large coordinates Resolution: Improvements have been made to the export of models with large coordinates. These reduce, but do not completely eliminate the visible offsets and shifts in this and similar examples.
Interop
Title: Inconsistency in TUBI Export Results Between E3D Versions: E3D 2.1.0.35 vs. E3D 3.1.8.1 Resolution: Fixed – Now exports correctly
Interop
Title: PSLIST export to IFC Resolution: Fixed – The missing tubes have been fixed
Interop
Title: Problem for Export STEP file of PSLIST Resolution: Fixed – TUBE elements from branches in SPOOLS should be now exported with rest of SPOOL elements.
Interop
Title: Import NWD using MultiCAD Resolution: Fixed – Note that this is a large and complicated model and it is important to use the “Limit no. of import elements per level” option (in the IMP command the option is for example “Bucketsize 300”). Complex imported models such as this are always relatively slow to work with. Unified Engineering is better for large models that E3D Design 3.1 series, as it can use more memory (as a 64-bit process) but both E3D Design 3.1 series and Unified Engineering can occasionally fail with very complicated models which can exceed various internal resource limits. Where possible, we recommend using simpler versions of the original CAD model, either with export options in the original system, or trying AVEVA Model Simplification
Interop
Title: Problem for Export STEP & RVM file of PSPOOL Resolution: Fixed – TUBE elements from branches in SPOOLS should be now exported with rest of SPOOL elements.
Interop
Title: When resizing the MEI Export Form some Buttons are stuck. Resolution: Fixed – toggle boxes are now correctly anchored.
Interop
Title: Closure element missing from ERM Integration attribute Resolution: Fixed – Added closure type
Interop
Title: Incorrect User defined name and Reporting text for Material Id when re-running the lexicon script. Resolution: Fixed
Interop
Title: Warning messages for MaterialID UDA when navigate from SBOL to DTAB Resolution: Fixed – Removed indexed UDA which removes this warning in all cases
Interop
Title: Unable to publish pipe part list due to validation error for NUT & WASHER Resolution: Fixed – Now able to preview the data. Also compared the bolt count with isometric
Interop
Title: Incorrect scale when importing STL models with MultiCad Resolution: Fixed – correct scaling values are imported. MultiCAD has been changed to assume that a STL file is defined in millimetres, which is common but not universal. Allowing the user to specify other units may be considered for future releases. The workaround for non-millimetre files is to use a SCALE and command line input.
Interop
Title: Extracting the PMTO from E3D 3.1.9 is not collecting the spool information generated by pipe fabrication in model design Resolution: Fixed – Resolved by incorporating spool information from pipe fabrication, which also supports the Spool module. The Spooler module will take precedence in this process
Interop
Title: RVM Export – TUBI missing while using GPSET hierarchy in E3D Resolution: Fixed – Exports correctly.
Interop
Title: Unable to import a bolting specification from ERM to E3D 3.1.8 Resolution: Fixed – The issue because of / in the spec name. This is now handled in the Spec import.
Interop
Title: PMTO generation in E3D is not working correctly – Imperial sizes are wrong Resolution: Fixed – Collecting correct imperial spec sizes. Handling short codes if SPCOs has -‘ The UNIT and Quantity mismatch has been fixed.
Interop
Title: Incorrect behaviour determined during export of TUBI elements under GPSET as RVM file. Resolution: Fixed.
Interop
Title: IFC file for importing into E3D but not all content is imported Resolution: Fixed
Interop
Title: Problem for Export STEP&RVM file of PSPOOL Resolution: Fixed – TUBE elements from branches in SPOOLS should be now exported with rest of SPOOL elements.
Interop
Title: Quantity not matching between E3D Isometric – > BULK MTO -> ERM Resolution: Fixed – Quantity was getting truncated which caused this issue.
Interop
Title: The Nulref error for the BSPEC attribute when importing Insulation Spec Resolution: Fixed
Hull
Title: Issue of memory for E3D Design 3.1.9 Resolution: Fixed – A new backstage option has been added to either optimize marine performance for speed or memory. The default behaviour is to optimize for speed, which can be changed in case of warnings of a of high memory consumption when drawing a large number of hull models in the canvas. This may typically happen when drawing the whole hull model of a ship rather than selected parts or individual blocks. The setting affects only models related to planar or curved hull.
Marine
Title: Problem with assigning the DINTER attribute Resolution: Fixed – DINTER attribute correctly output to DATAL file.
Marine
Title: Aveva Hull modeler SP5 shell profiles not visible in Aveva E3D 3.1.7.2 Resolution: Fixed – shell stiffeners are clearly visible with notches & Endcuts in 3D canvas
Marine
Title: Inaccurate representation of stiffeners in E3D Resolution: Fixed – end cuts are appearing correctly for the identified stiffeners.